Direct in-scope suction: an in vitro evaluation of a single use flexible ureteroscope with ......
Date: 2024-09-01 Click: 107

文献封面240901.png


Authors

Aideen Madden, Paris, France; Carlos Altez, Coruna, Spain; Jordi Pena Lueza, Lleida, Spain; Razvan Popescu, Bucharest, Romania; Johan Cabrera, Mariela Corralles, Olivier Traxer, Paris, France


Abstract


Purpose

To evaluate the stone clearance rate and limitations of a novel integrated suction capability within a single-use flexible ureteroscope according to stone particle size.

Methods

Varying sized stone particles were created using a stone phantom (Begostone Plus, Bego ©, Lincoln, RI, USA). Particle size ranged as follows: 63–125 µm, 125–250 µm, 250–500 µm, 500 µm- 1 mm and 1–2 mm. These were mixed with Normal saline (0.9%) to mimic in vivo conditions. The suction enabled single-use flexible ureteroscope (Pusen, Zhuhai, China) was used to aspirate stone fragments in three trials. Firstly, aspiration of 5 g of each dust range was attempted. Secondly, a direct comparison of the integrated suction to a manual syringe technique was applied to 1 g of each size range. Finally, aspiration was applied to 5 g of a heterogenous 1:1:1:1:1 mixture. Endoscopic clearance rate (g/min) and number of blockages were recorded. Each challenge was repeated three times.

Results

The integrated suction cleared 100% of dust < 250 µm. Endoscopic clearance rates were significantly faster than manual aspiration (3.01 g/min versus 0.41 g/min) for dust between 125 and 250 µm (p = 0.008). Complete endoscopic clearance by 180 s (without encountering test limiting blockages) was unsuccessful for particles > 250 µm. Clearance rates were greatly limited by stone particle size heterogeneity above 250 µm, to 0.09 g/min.

Conclusion

This technology works better in vitro than previously DISS evaluated methods when challenged by stone dust < 250 µm. However, this adaptation is significantly challenged in the presence of stone dust particles > 250 µm.

Keywords

DlSS; Direct-in-scope suction; Suction; Ureteroscopy


Literature Link >>>


Previous: First clinical evaluation of a flexible digital ureteroscope with direct in scope suctioning......
Next: Which sucks more? Comparison of two novel direct-in-scope suction ureteroscopes......
Products
  • Urology
  • Hepatobiliology
  • Airway Management
  • Accessories
News
  • Company News
  • Exhibitions & Events
Science
  • Ureteroscope
About
  • Development History
  • Marketing Worldwide
  • Honor
  • Love & Responsibility
Contact
  • Contact us & Feedback
  • Benefits & Rewards
  • Grow with PUSEN

Follow us to learn more
about the latest news

5/F, Building 1, No 33, Keji San Road,

High-tech Zone, Tangjiawan Town,

519085 Zhuhai, Guangdong, People's Republic of China

(86) 400-688-2023

pusen@pusenmedical.com


©2023 Zhuhai Pusen Medical Technology Co., Ltd.  All Rights Reserved  
 互联网药品信息服务资格证书(粤)- 非经营性 - 2022 - 0297    粤ICP备18073173号-1    1710149628862846.png 
粤公网安备44049102496975号

反馈收集单